RAH INDUSTRIES INC -
NADCAP Approved
90024594
Independent Processor
24800 AVENUE ROCKEFELLER
VALENCIA , CA 91355 United States
Phone: 6612955190
Fax:
90024594
Independent Processor
24800 AVENUE ROCKEFELLER
VALENCIA , CA 91355 United States
Phone: 6612955190
Fax:
Selected sector: AS
Specification
ProcessDescription
Category
Process Specification for Etching Prior to Penetrant Inspection
Chemical Processing
Limits:
Aluminum only. Ref. RC/I BR435159 & BR435158
Welding of Tubular Joints
Welding
Limits:
None
Process Specification for Sealing, Integral Fuel Tank and Fuel Cell Cavity
Finishes/Coatings
Limits:
Type II sealants.
Not approved for Appendix A
Cleaning and surface preparation of titanium and titanium alloys
Chemical Processing
Limits:
Para. 3.3.2.1 Method A and B
Not approved for Appendix A
Penetrant Inspection
Non-Destructive Testing
Limits:
Type I, Method A, Sensitivity Level 3, form D developer. Excludes Appendix B
Standard Practice for Liquid Penetrant Testing
Non-Destructive Testing
Limits:
None
Fusion Welding for Aerospace Applications
Welding
Limits:
GTAW Only
Chemical Conversion Coatings for Aluminum and Aluminum Alloy
Chemical Processing
Limits:
Limited to Type I only.
Fusion Welding for Aerospace Applications
Welding
Limits:
GTAW Only