STEELVILLE MANUFACTURING CO - NADCAP Approved
90068157
Independent Processor
1056 PERKINS DR
STEELVILLE , MO 65565 United States
Phone: 573-775-2977
Fax: 573-775-5093
Selected sector: AS

Specification
ProcessDescription
Category
Finish Specification for F-35 Weapon System. Note* Approval for this specification is required in conjunction with MIL-PRF-8625 for appropriate anodize seal requirements
Limits:
This specification shall be used in conjunction with MIL-PRF-8625 for appropriate anodize seal requirements

Process Specification for Etching Prior to Penetrant Inspection
Chemical Processing
Limits:
None

Process Specification for Sealing, Integral Fuel Tank and Fuel Cell Cavity
Finishes/Coatings
Limits:
Not approved for Appendix A

Cleaning and surface preparation of titanium and titanium alloys
Chemical Processing
Limits:
Grit Blast only. Not approved for Appendix "A"

Process Specification for Contamination Free Hole Preparation, Drilling, Machining and Trimming of Composites and Composite/Metallic Structures
Composites
Limits:
Machining/Drilling of mechanically Fastened Non-Metallic Detail Parts

Penetrant Inspection
Non-Destructive Testing
Limits:
Limits: Not Approved for Appendix B

Passivation Treatments for Corrosion-Resistant Steel
Chemical Processing
Limits:
Limited to Method I, Type 6

Heat Treatment Precipitation-Hardening CRES and Maraging Steel Parts
Heat Treat
Limits:
Limited to furnace #2

Heat Treatment of Wrought Aluminum Alloy Parts
Heat Treat
Limits:
Limited to furnace #2

Heat Treatment of Titanium Alloy Parts
Heat Treat
Limits:
Limited to Stress Relieve only, furnace #2

Standard Practice for Operating Salt Spray (Fog) Apparatus
Miscellaneous
Limits:
None

Descaling & Cleaning Titanium and Titanium Alloy Surfaces
Chemical Processing
Limits:
None

Standard Practice for Liquid Penetrant Testing
Non-Destructive Testing
Limits:
None

Hardness and Conductivity Testing
Miscellaneous
Limits:
None

Fluorescent Penetrant Inspection of Metallic Parts & Materials
Non-Destructive Testing
Limits:
Limited to normal control non-critical parts

Etch/Cleaning Prior to Penetrant Inspection
Chemical Processing
Limits:
Aluminum alloys only Alternate etch solution per RCI B R443413

Touch-up Requirements for Chemical and Organic Finishes
Chemical Processing
Limits:
None

Application and Control of Organic Finishes
Chemical Processing
Limits:
None

Chemical Conversion Coatings for Aluminum and Aluminum Alloy
Chemical Processing
Limits:
Type 1 only

Anodic Coatings For Aluminum and Aluminum Alloys
Chemical Processing
Limits:
Types IC, II, IIB, and IIl