Specification
|
Process Description
|
Category
|
Limits
|
2ZZP00001
|
Finish Specification for F-35 Weapon System. Note* Approval for this specification is required in conjunction with MIL-PRF-8625 for appropriate anodize seal requirements
|
|
Limits:
Approval based on QCS-001 and subject to the limitations listed on QCS-001 |
ASTM B117
|
Standard Practice for Operating Salt Spray (Fog) Apparatus
|
Miscellaneous
|
Limits:
None
|
ASTM E1417
|
Standard Practice for Liquid Penetrant Testing
|
Non-Destructive Testing
|
Limits:
Type I, Method A, Sensitivity Level 3, Form d |
GSS 4310
|
Application of Primer Coating, Epoxy Polyamide
|
Chemical Processing
|
Limits:
Force Cure per Approved RCI BR 631876 |
GSS 4510
|
Coating, Polyurethane, Application of
|
Chemical Processing
|
Limits:
None
|
LMA-PC009
|
Hardness and Conductivity Testing
|
Miscellaneous
|
Limits:
None
|
LMA-PC201
|
Fluorescent Penetrant Inspection of Metallic Parts & Materials
|
Non-Destructive Testing
|
Limits:
Facility requalification was conducted the week of March 14, 2022. Based on the requirements called out in LMA-PC201, Appendix A. The following personnel successfully completed qualification demonstration:Tracy Roseman..stamp # 747
Matt Eoff..stamp # 466, Dustin Rolens..stamp # 1054
This task was accomplished using procedure # STP-05-8.2.4, Revision U in conjunction with critical parts planning template.
Expires 03/2025
|
LMA-PG001
|
Etch/Cleaning Prior to Penetrant Inspection
|
Chemical Processing
|
Limits:
Aluminum only |
LMA-PJ264
|
Application and Control of Organic Finishes
|
Chemical Processing
|
Limits:
Approval based on QCS-001 and subject to the limitations listed on QCS-001 |
MIL-DTL-5541
|
Chemical Conversion Coatings for Aluminum and Aluminum Alloy
|
Chemical Processing
|
Limits:
Limited to Type 1 only |
MIL-PRF-8625
|
Anodic Coatings For Aluminum and Aluminum Alloys
|
Chemical Processing
|
Limits:
Dichromate seal is required when Mil-PRF-8625 Type II anodize is called out on engineering drawings. |