Northrop Grumman Approved Special Processors Listings - Supplier Report
AIRCRAFT FINISHING CORP : 90054292 - Independent Processor - NADCAP Approved
612 RUTGERS RD
WEST BABYLON , NY 11704-5555 United States
Phone: 631-422-5000    Fax: 613-422-0815
Selected sector: AS

Specification ProcessDescription Category SpecLimits
AMS 2700 Passivation Treatments for Corrosion-Resistant Steel Chemical Processing Limits: Limited to Method 1; Types 2, 6 and 8
AMS-QQ-P-416 Plating, Cadmium (Electrodeposited). Chemical Processing Limits: None
ASTM E1417 Standard Practice for Liquid Penetrant Testing Non-Destructive Testing Limits: None
ASTM E1444 Standard Practice for Magnetic Particle Testing Non-Destructive Testing Limits: None
FP-153 Primer MIL-P-85582, Epoxy, Voc Compliant, Application of Chemical Processing Limits: Limited to Aluminum and Alum Alloys only
FP-28 Chemical Conversion Coatings, Colored, for Aluminum and Aluminum Alloys Chemical Processing Limits: None
FP-87 Sulfuric Acid Anodizing of Aluminum and Aluminum Alloys Chemical Processing Limits: None
GP 17 G Procedure, Etching prior to Penetrant Inspection Chemical Processing Limits: Limited to Aluminum Alloy parts
GSS 4306 Integral Fuel Tank Coating (MILC27725) Application of Chemical Processing Limits: None
GSS 4310 Application of Primer Coating, Epoxy Polyamide Chemical Processing Limits: Force Air Drying Cycles shall be in accordance with RC/I R631876 (254304).
GSS 4407 Application of Lacquers: Acrylic Chemical Processing Limits: Supplier is Utilizing an Approved Product Substitution –authorized per GP110AEF polyurethane per GS30BF - sheet 46
GSS 4510 Coating, Polyurethane, Application of Chemical Processing Limits: None
GSS 5100 Heat Treatment of Low Alloy Steel Heat Treat Limits: Limited to Stress Relieving only.
GSS 7021 Acid Cleaning of Ferrous Alloys Chemical Processing Limits: None
GT 23 A Fluorescent Penetrant Inspection Non-Destructive Testing Limits: None
IT-60 Penetrant Inspection Non-Destructive Testing Limits: None
MIL-DTL-5541 Chemical Conversion Coatings for Aluminum and Aluminum Alloy Chemical Processing Limits: Limited to Type 1 only
MIL-PRF-8625 Anodic Coatings For Aluminum and Aluminum Alloys Chemical Processing Limits: Limited to Type 1 and Type 2. 5% sodium dichromate seal is required when MIL-PRF-8625 is called out for anodizing on the AEW/AGS engineering drawing.
NGT23K Magnetic Particle Method of Inspection for Non-Destructive Test Non-Destructive Testing Limits: None