Northrop Grumman Approved Special Processors Listings - Supplier Report
BARNES GROUP INC : 90049034 - Independent Processor - NADCAP Approved
1025 S. Depot Drive
OGDEN , UT 84404 United States
Phone: 8019172088    Fax: 801-917-2033
Selected sector: AS

Specification ProcessDescription Category SpecLimits
2ZZP00013 Fusion Welding Welding Limits: Limits: Limited to Group VI, Titanium
AMS 2801 Heat Treatment of Titanium Alloy Parts Heat Treat Limits: Limited to stress relief only
AMS-H-81200 Heat Treatment of Titanium and Titanium Alloys Heat Treat Limits: None
AMS-W-6858 Welding, Resistance: Spot and Seam Welding Limits: None
ASTM B600 Descaling & Cleaning Titanium and Titanium Alloy Surfaces Chemical Processing Limits: None
ASTM E1417 Standard Practice for Liquid Penetrant Testing Non-Destructive Testing Limits: None
ASTM E1742 Standard Practice for Radiographic Examination Non-Destructive Testing Limits: None
AWS D17.1 Fusion Welding for Aerospace Applications Welding Limits: Limited to GTAW for Groups III & VI. Visual weld inspectors qualified to AWS B5.2
AWS D17.2 Resistance Welding for Aerospace Applications Welding Limits: No Limits. Visual weld inspectors are qualified to AWS B5.2
EPFS-322 Forming and Straightening of Titanium Alloys Miscellaneous Limits: None
GP 17 G Procedure, Etching prior to Penetrant Inspection Chemical Processing Limits: Limited to Titanium alloys
GSS 4310 Application of Primer Coating, Epoxy Polyamide Chemical Processing Limits: Reference Force dry RCI #BR020920
GSS 4510 Coating, Polyurethane, Application of Chemical Processing Limits: None
GSS 5360 Forming of Titanium and Titanium Alloys Miscellaneous Limits: None
GSS 5361 Superplastic Forming of Ti-6Al-4v Titanium Alloy Miscellaneous Limits: None
GSS 7015 Cleaning and Descaling of Titanium and Titanium Alloys Chemical Processing Limits: Limited to Methods 1, 2, 3, 4 & 7 only
GT 23 A Fluorescent Penetrant Inspection Non-Destructive Testing Limits: None
LMA-PC201 Fluorescent Penetrant Inspection of Metallic Parts & Materials Non-Destructive Testing Limits: The following personnel met the requirements for initial and requalification:Cindy Glisson….Employee # 900830 …stamp #4 Joe Daniels...Employee # 667025…stamp # 12 This task was accomplished using procedure # FPS 51.11, Addendum N, Revision 5, released 02/04/2016 and PT General Procedure FPS 51.11, Revision 51, released 02/17/2020 Processing of Critical Parts as defined by LMA-PC201 is limited to those individuals named above. Expires 01/2025.
LMA-PC301 Radiographic Inspection Non-Destructive Testing Limits: None
LMA-PG001 Etch/Cleaning Prior to Penetrant Inspection Chemical Processing Limits: Limited to titanium parts only