Northrop Grumman Approved Special Processors Listings - Supplier Report
HOUSTON PRECISION FASTENERS LLC: 90067570 - Manufacturer - NOT NADCAP Approved
4923 CRANSWICK RD
HOUSTON, TX 77041-7723 United States
Phone: 7134622227    Fax: 713-456-2471
Selected sector: AS

Specification ProcessDescription Category SpecLimits
29259-18 Fluorescent Penetrant Inspection Non-Destructive Testing Limits: Type 1, Method A, Sensitivity Level 2, & 4. No etch capability
ACS-PRS-7005 Penetrant Inspection Non-Destructive Testing Limits: Type 1, Method A, Sensitivity Level 2, & 4. No etch capability, Appendix B Applies
AMS 2700 Passivation Treatments for Corrosion-Resistant Steel Chemical Processing Limits: Method 1, Type 8
AMS 2759 General Requirements for Heat Treatment of Steel Parts Heat Treat Limits: Class A Argon Atmosphere Only
AMS 2759/3 Heat Treatment Precipitation-Hardening CRES and Maraging Steel Parts Heat Treat Limits: None
AS5272 Lubricant, Solid Film, Heat Cured, Corrosion Inhibiting Procurement Specification. Superseding MIL-PRF-46010 for Types I & II only Chemical Processing Limits: None
ASTM E1417 Standard Practice for Liquid Penetrant Testing Non-Destructive Testing Limits: None